TECHNICAL SPECIFICATIONS
Smart Trac ultraMeasurements
Frequency
From 0 Hz to 32000 Hz
Acceleration
Up to 16 g
Velocity
Up to 100 mm/s RMS
Temperature
From -40°F to 230° F (-40°C to 110°C)
Sample Configuration
32768 lines (per axis)
Default Setting
Samples every 5 minutes
Sampling Frequency
500Hz (64s), 1000 Hz (32s), 2000 Hz (16s), 4000Hz (8s) , 8000Hz (4s) 16000Hz (2s), 32000Hz (1s)
Wireless Communication
Frequency
915MHz ISM
Protocol
IEEE 802.15.4g
Connectivity
LTE/4G mobile networks, with no need to rely on industrial Wi-Fi
Bands
6 frequency channels, dynamically assigned
Internal Environment Range
Up to 330ft (100m) between sensor and receiver, depending on the industrial plant topology
Line of Sight Range
Up to 3,300ft (1km) between sensor and receiver, depending on the industrial plant topology
Physical Characteristics
Dimensions
40 (W) x 71 (H) x 40 (D) mm or 1.6 (W) x 2.8 (H) x 1.6 (D) in, excluding sensor base
Weight
180g / 6.4 oz (sensor) 22g / 0.8oz (shorter base) 50g / 1.75oz (taller base)
External Material
Lexan™
Fixation
Sensor base must be glued or screwed to the asset
Electronic Sealing
100% Resin Coated
Cybersecurity
Sensor to Receiver Communication
Encrypted AES (128 bits)
Certification
FCC
Environmental Characteristics
IP Rating
IP69K
Humidity
Suitable for installation in high humidity areas
Operating Temperature
From -40°F to 230° F (-40°C to 110°C)
Hazardous Locations
Complies with ATEX, NFPA 70 CL1, CL2, and CL3 (All Division I).
POWER SOURCE
Battery
Lithium battery
Duration
Between 3-5 years on default settings
Adverse Factors
Temperature, transmission distance, and data acquisition configuration