Key Points
- Broken rotor bars and stator shorts show up most clearly in current, voltage or magnetic flux data.
- Ask each vendor which signals its motor sensors measure, because that decides which electrical faults it can catch.
- Check the path from alert to repair: automated diagnosis, human review when needed, and a work order in your CMMS.
Choosing the best machine health monitoring for motors starts with the faults your motors actually develop. On a plant floor full of AC induction motors driving pumps, fans and conveyors, that means mechanical faults (bearings, imbalance, misalignment, looseness) and electrical faults (rotor bars, stator windings, supply problems).
This guide compares five systems maintenance teams evaluate for motors: Tractian, Fluke, Augury, SKF and AssetWatch. The fault coverage table shows which motor faults each product covers.
For a broader comparison across asset types, read the guide to machine health monitoring solutions.
What should a motor monitoring system detect?
A motor monitoring system should detect the mechanical and electrical faults that cause most motor failures, early enough to plan the repair. Mechanical faults appear in vibration and ultrasound; electrical faults appear most clearly in current, voltage or magnetic flux.
Mechanical faults: bearings, imbalance, misalignment, looseness
Bearing defects produce energy at specific bearing fault frequencies (BPFO, BPFI, BSF and FTF) well before the bearing runs hot. Ultrasound picks up friction from poor lubrication even earlier, which matters on slow motors where vibration energy is low.
Imbalance shows up as a strong peak at running speed in the radial direction. Misalignment between the motor and the driven pump or gearbox shows up at one and two times running speed, often with high axial vibration; the types of misalignment (angular, parallel, combined) leave different patterns. Looseness adds harmonics and impacts to the waveform.
Electrical faults: rotor bars, stator windings, supply unbalance
A cracked rotor bar creates sidebands around line frequency in the motor current, and the motor starts to pulse under load. Stator inter-turn shorts, uneven air gaps and voltage unbalance from the supply raise winding temperature and shorten insulation life.
Vibration can hint at some of these faults, but it cannot separate a weak supply from a failing winding. Electrical signature analysis reads the current and voltage waveforms and points to the supply, the drive, the cable or the motor itself.
Motor fault coverage by vendor
Confirm any fault marked not stated or not itemized with the vendor during evaluation.
| Motor fault | Tractian | Fluke | Augury | SKF | AssetWatch |
|---|---|---|---|---|---|
| Signals measured | Vibration, ultrasound, temperature and RPM (Smart Trac Ultra); panel-level electrical monitoring (Energy Trac) | Triaxial vibration and temperature (3563 sensor) | Triaxial vibration, temperature and magnetic flux (Halo R4000) | Vibration and temperature (Enlight Collect IMx-1) | Vibration and temperature sensors; 3-phase current through in-panel clamps; oil analysis |
| Bearing faults | Bearing wear, BPFO and BPFI defects, lubrication failures | Bearing damage, a named target fault of the 3563 | Bearing wear tracked through vibration and acoustic signatures | Bearing damage | Bearing condition and lubrication health in the motor program |
| Imbalance | Named as unbalance by Auto Diagnosis | Among the 3563 target faults | Phase analysis on supported sensors | Not itemized; covers common rotating-equipment issues | Listed in the motor monitoring program |
| Misalignment | Detected and named by Auto Diagnosis | A core fault for the 3563 | Covered; phase analysis on supported sensors | Not itemized | Listed in the motor monitoring program |
| Electrical faults | Rotor and stator faults, voltage imbalance (Energy Trac) | Not stated for the 3563 sensor | Rotor bar, stator winding and air gap faults via magnetic flux | Not stated for the IMx-1 sensor | Overcurrent, undercurrent, current unbalance and winding degradation from motor current |
| Hazardous-area option | Class I Div 1, ATEX, IECEx and NFPA 70 | Not stated (sensor rated IP67) | Hazardous model: Class I Zone 0, ATEX, IECEx, CSA Div 1 | ATEX and IECEx, Zones 1 and 2 (IMx-1-EX) | Not stated |
| Human review | Automated diagnosis, with human review by Tractian reliability engineers when needed | Setup help from Fluke Reliability; remote condition monitoring offered as a service | Human support and services offered alongside the platform | Not stated | Human review by a condition monitoring engineer |
| Pricing model | Custom quote scoped to your assets | Sold as kits of sensors, gateways and software subscriptions | Not published; quoted after a demo | Sold through SKF distributors | One monthly subscription |
1. Tractian
Best for: Plants that want mechanical and electrical motor faults diagnosed in one platform, with wireless sensors that install quickly and connect to the CMMS they already run.
Tractian's condition monitoring platform pairs two sensors on each motor. Smart Trac Ultra mounts on the motor and streams vibration, ultrasound, temperature and RPM, sampling at up to 64 kHz. Energy Trac adds panel-level electrical monitoring and installs non-invasively, without stopping the process.
Auto Diagnosis turns vibration and ultrasound patterns into named faults such as bearing wear, misalignment and unbalance, benchmarked against millions of historical machine hours and a bearing library. On the electrical side, Energy Trac detects rotor, stator, winding and insulation faults and voltage imbalance.
- Fast setup: Sensors are wireless, go live over LTE without plant Wi-Fi, and run 3 to 5 years on a battery, with expert support from Tractian during install.
- Hazardous and washdown areas: Smart Trac Ultra is IP69K sealed, ATEX/IECEx compliant and Class I Div 1 certified, with NFPA 70 Class 1, 2, and 3 (Division I) compliance.
- Integrations: Alerts become work orders inside Tractian or flow to existing CMMS, ERP and EAM systems through Tractian integrations.
- Human review: Tractian reliability engineers review findings with your team when a call needs a second opinion.
Motor results from Tractian customers
At Cadillac Casting, Tractian flagged bearing wear and fast-dropping lubrication on a 200 HP motor shortly after install. The supervisor swapped the motor over a weekend, and the teardown found a locked bearing rubbing on the shaft. At go-live, the platform also caught a lubrication issue on a drag shakeout motor, which the team greased on the spot.
A Unilever food plant in Latin America covered 40 critical assets, blower motors included, with 320 sensors. In 112 days it anticipated 19 failures and avoided 117 hours of unplanned downtime. Tractian runs similar programs across food and beverage and manufacturing plants.
Tractian pricing
Tractian pricing for motor monitoring is scoped to your motor list. A specialist reviews which motors are critical, how they tend to fail (bearings, alignment, windings, supply), and whether each one needs mechanical sensing, electrical sensing or both. The custom quote is priced around that coverage, so a plant can start with its most critical motors and add the rest later.
Questions to ask before you buy
- Can one platform cover both mechanical and electrical motor faults?
- Will the system catch lubrication problems before damage starts?
2. Fluke
Best for: Teams that want triaxial vibration and temperature sensors reporting to eMaint software.
The Fluke 3563 Analysis Vibration Sensor uses two MEMS sensors for the X and Y axes (0 to 1,000 Hz) and a piezoelectric sensor on the main Z axis (2 Hz to 10 kHz). It records RMS and peak-to-peak vibration, time waveforms and temperature, and it targets four faults: imbalance, misalignment, looseness and bearing damage.
- Connectivity: Sensors send data to a gateway over a 2.4 GHz short-range link; the gateway connects over Wi-Fi or Ethernet.
- Software: eMaint sets thresholds from asset details and shows bearing severity overalls, trend charts and frequency bands.
- Battery and rating: Transmission intervals are user-set (minimum default of 10 minutes), with battery life of at least one year at that rate; the sensor is rated IP67.
- Setup: Kits include remote or onsite setup with help from Fluke Reliability.
Fluke pricing
Price comes from Fluke or a distributor.
3. Augury
Best for: Plants that want vibration, temperature and magnetic flux from one motor sensor, with AI diagnostics and support services from Augury's team.
The Halo R4000 sensor captures triaxial vibration, temperature and magnetic flux. Augury uses the flux reading to confirm the motor is running, calculate its speed, and identify electrical faults such as broken rotor bars, stator winding problems and air gap variation.
- Diagnostics: Supported sensors offer phase analysis for imbalance and misalignment.
- Connectivity and rating: R4000 sensors connect over Bluetooth Low Energy to a gateway that handles up to 64 sensors, with IP66, IP68 and IP69 protection.
- Hazardous areas: A separate hazardous-classified model is approved for Class I Zone 0 and certified to ATEX, IECEx and CSA Div 1 and uses ISA100.11a wireless.
- Work orders: Findings go to the CMMS or EAM with fault, severity and recommended action, and the completed repair is logged back in Augury.
Augury pricing
Augury prices are quoted after a demo rather than published.
4. SKF
Best for: Teams that want battery-powered vibration and temperature sensors on a mesh network, feeding SKF analysis software.
The SKF Enlight Collect IMx-1 sensor measures and processes vibration and temperature to detect common issues with rotating equipment. Sensors relay data to one another over a low-energy mesh network to a gateway and the host software.
- Hazardous areas: The IMx-1-EX version carries ATEX and IECEx certification for Zones 1 and 2 and works with a Zone 2 gateway.
- Bearings: The IMx-1 family targets bearing damage.
- Mixed fleets: EX and safe-area sensors share form and function and run on the same network.
SKF pricing
SKF sells the IMx-1 system through its distributors, so pricing comes from a distributor quote.
5. AssetWatch
Best for: Plants that want a subscription monitoring service where an assigned person reviews findings before they reach the team.
AssetWatch combines vibration, temperature, electrical and oil analysis data in one platform. Its motor program tracks bearing condition, lubrication health, imbalance, misalignment, looseness and drive train issues, and a condition monitoring engineer reviews findings and recommends actions.
- Electrical monitoring: In-panel current transformer clamps on AC motors measure 3-phase current, RPM and panel temperature, and flag overcurrent, undercurrent and current unbalance.
- Connectivity: Sensors use a cellular network.
- Work orders: Recommendations are delivered to the customer's CMMS.
AssetWatch pricing
AssetWatch prices are quoted after a demo rather than published.
Questions to ask any vendor about motor coverage
- Which electrical faults does the system detect, and from which signal?
- What sample rate does the sensor use on slow motors, and what is the lowest shaft speed it has been used on?
- Who reviews an alert before it reaches the technician, and how long does that take?
- Does the alert name the failure mode?
- How does a finding become a work order, and does it carry the fault, severity and recommended action?
- Which CMMS connectors are included?
- How does cost change as you add motors, from the first 20 critical motors to the full fleet?
How to choose a system for your motor fleet
Pick the system that fits the motors that cause the most downtime, then confirm it covers the faults they show.
| Motor situation | What to require | Why it matters |
|---|---|---|
| VFD-driven motors on pumps and fans | Current and voltage monitoring that tracks speed, load and drive behavior together | Drive faults and supply sags can look like mechanical trouble in vibration data alone |
| Slow gearmotors on conveyors and mixers | High sample rates plus ultrasound for early bearing friction | Low-speed bearing defects produce weak vibration energy |
| Motors in Class I Div 1 or ATEX zones | Sensors certified for the zone, with no conduit or hot work to install | An uncertified sensor cannot be mounted in the classified area |
| Washdown areas in food plants | IP69K sealing for high-pressure, high-temperature cleaning | Sanitation cycles spray high-pressure hot water directly on motors and sensors |
| Sites without usable plant Wi-Fi | Cellular or LTE connectivity that skips the plant network | New Wi-Fi devices usually need plant IT approval before install |
| Small team, no vibration analyst | Automated fault diagnosis with a named failure mode, plus human review on request | Raw spectra are hard to act on without trained analysts |
Learn more about motor monitoring. For vendor-by-vendor detail, compare Fluke alternatives, Augury alternatives, SKF alternatives and AssetWatch alternatives.
Frequently Asked Questions
Can vibration sensors detect electrical faults in motors?
Some electrical faults leave a mark in vibration, such as twice line frequency peaks from stator or air gap problems, but the signal is indirect and easy to confuse with mechanical causes. Current, voltage and magnetic flux measure the electrical behavior directly, so broken rotor bars, stator shorts and supply unbalance show up earlier and with less ambiguity. Many plants pair a vibration sensor on the motor with current monitoring in the panel.
What is the difference between motor current signature analysis and magnetic flux monitoring?
Motor current signature analysis reads the current drawn by each phase, usually with clamps in the motor control panel, and looks for fault frequencies in that waveform. Magnetic flux monitoring measures the stray magnetic field around the motor frame with a sensor mounted on the motor. Both can reveal rotor and stator problems; current analysis also sees supply and drive issues upstream of the motor.
Which motors should a plant monitor first?
Start with motors whose failure stops a line or has no installed spare: main drive motors, critical pump and fan motors, and large compressor motors. Then add motors with a history of repeat bearing failures. Many plants start with a short list ranked by criticality and expand once the first alerts prove out.
Do wireless motor sensors need plant Wi-Fi?
That depends on the gateway. Some gateways connect over plant Wi-Fi or Ethernet, while others use cellular or LTE links that bypass the plant network. Tractian sensors go live over LTE, which avoids a new device request to plant IT.
See Tractian Motor Monitoring on Your Own Motors
Bring a list of your critical motors and recent failures. A Tractian specialist will show which faults Smart Trac Ultra and Energy Trac would catch on each one, how alerts reach your team, and what coverage would cost. Book a Tractian condition monitoring demo.