Key Points
- Rotating equipment faults usually start as a mechanical or electrical change that the right sensor can read before the asset stops.
- Legacy route-based monitoring reads a machine once per technician visit, so a fault that starts between readings can grow unseen.
- Wireless multimodal monitoring pairs a mechanical sensor on the asset with electrical monitoring in the panel, diagnosed by one AI model.
The right CBM sensors for rotating equipment depend on the fault you need to catch. Bearing wear, imbalance and misalignment show up in vibration and ultrasound on the machine, while rotor, stator, winding and insulation faults show up first in the motor's current and voltage.
Legacy condition monitoring systems from vendors such as SKF, Emerson and Siemens grew up around portable route collectors and wired online monitors. Tractian takes the modern route: a wireless sensor on each critical asset, electrical monitoring in the panel that feeds its motor, and an AI model that reads both together.
What do CBM sensors measure on rotating equipment?
CBM sensors on rotating equipment measure two groups of signals: mechanical signals taken on the machine (vibration, ultrasound, temperature and speed) and electrical signals taken on the motor circuit (current, voltage and power factor). Each group catches a different set of failure modes.
Condition-based maintenance works when the sensor reads the signal the failure actually produces. A vibration sensor on a motor housing can report a healthy bearing while the stator insulation is breaking down.
Mechanical signals: vibration, ultrasound, temperature and RPM
Vibration is the main signal for imbalance, misalignment, looseness and bearing defects. A vibration sensor with a wide frequency range picks up bearing defect frequencies long before they show up as heat or noise on the floor.
Ultrasound reads friction and lubrication problems at the high end of the spectrum, which makes it useful on slow bearings and on grease intervals. Temperature confirms a fault that is already producing heat, and RPM lets the software line up fault frequencies with the actual shaft speed on variable-speed drives.
Electrical signals: current, voltage and power factor
Electrical monitoring reads the motor from its supply circuit. Changes in current, voltage and power factor point to rotor, stator, winding and insulation faults, and to power quality problems such as voltage imbalance, harmonics and sags.
These faults can develop with little change in vibration, which is why a mechanical sensor alone leaves them out. Motor current signature analysis is the classic method for reading them from the current waveform.
What are the main CBM sensor approaches for rotating equipment?
Plants use four sensor approaches on rotating equipment: portable route collectors, wired online systems with protection racks, single-signal wireless sensors, and wireless multimodal monitoring. The first two are the legacy setups, and the last one is where Tractian works.
Portable route collectors
A technician walks a route with a handheld data collector, takes vibration readings at marked points, and an analyst reviews the spectra afterward. SKF, for example, offers portable instruments for this kind of periodic monitoring program. Coverage depends on how often the route runs and on whether the analyst who built it is still on site.
A bearing fault that starts two days after a monthly reading has weeks to grow before anyone looks at that machine again.
Wired online systems and protection racks
Wired systems cable accelerometers or proximity probes back to a monitor in a cabinet or rack, giving continuous data on the points that are wired. Protection racks add trip logic for large turbomachinery. Examples include SKF wired on-line and protection systems, Emerson machinery protection, and Siemens SIPLUS CMS, which records machine data inside the plant's automation system.
The trade-off is the install work: cable runs, conduit, cabinet space and a shutdown window for each machine added. Electrical faults still sit with a separate tool or survey.
Single-signal wireless sensors
Battery-powered wireless sensors removed the cable runs and made continuous monitoring affordable on balance-of-plant assets. Most read vibration and surface temperature, often over a gateway that relies on plant WiFi or Ethernet.
They close the gap between route visits, though they still leave the electrical side of the motor unmonitored.
Wireless multimodal monitoring
Tractian multimodal monitoring combines mechanical monitoring on the asset with electrical monitoring on the motor circuit. Smart Trac Ultra reads vibration, ultrasound, temperature and RPM on one asset, and Energy Trac reads current, voltage and power factor from the electrical panel.
Janus, Tractian's industrial AI, is trained on proprietary data from real machines and correlates both signal sets with operating context and maintenance history to point to the likely cause.
How do the approaches compare on signals, mounting and hazardous areas?
Tractian wireless multimodal monitoring reads both sides from one setup: four mechanical signals on the asset, three electrical signals from the panel, no cable runs, and sensors that are Class I Div 1 ATEX/IECEx/NFPA compliant. Route collectors and wired racks need separate tools for the electrical side.
Non-Tractian columns show general industry ranges, so specific products in each category may differ.
| Feature | Tractian wireless multimodal | Portable route collectors (e.g. SKF) | Wired online systems and protection racks (e.g. SKF, Emerson, Siemens) | Single-signal wireless sensors |
|---|---|---|---|---|
| Signals on the asset | Vibration, ultrasound, temperature and RPM from Smart Trac Ultra | Vibration readings taken by a technician, with ultrasound often on a separate handheld | Vibration and position probes cabled to a monitor | Usually vibration and surface temperature |
| Electrical signals | Current, voltage and power factor from Energy Trac in the panel | Separate motor test tool or electrical survey | Separate system or electrical survey | Not part of the sensor |
| How often data arrives | Continuous, sampled at 10-minute intervals by default | Once per route visit, often once a month | Continuous on the cabled points | On a fixed interval set by the vendor |
| Vibration bandwidth | 0 to 64,000 Hz, up to 60 g | Set by the handheld and probe used | Set by the probe and monitor card | Often a narrower band than wired probes |
| Mounting and wiring | Adhesive or drill-and-tap on the asset, no cable runs | Magnet or stud at marked points on each visit | Cable runs, conduit and a cabinet or rack | Stud or adhesive mount, battery powered |
| Network path | Sensor to receiver, receiver on 4G/LTE | Data downloaded after the route | Plant network or dedicated cabling | Gateway on plant WiFi or Ethernet in many setups |
| Hazardous areas | Class I Div 1 ATEX/IECEx/NFPA compliant | Depends on the handheld rating | Depends on probes, barriers and cabinet design | Varies by model |
| Who reads the data | Janus diagnosis with severity and a next step | Vibration analyst reviews spectra after the route | Vibration analyst or rack alarm setpoints | Threshold alarms, analyst for diagnosis |
Which approach fits which rotating asset?
Motors, pumps, gearboxes, fans and compressors each fail in mechanical and electrical ways, so the strongest fit on critical units is a mechanical sensor on the asset plus electrical monitoring on its motor circuit. On a motor, for example, vibration reveals a worn bearing while current and voltage reveal a failing winding.
| Asset | Faults mechanical data catches | Faults that need electrical data | What a legacy setup adds | Tractian setup |
|---|---|---|---|---|
| Electric motors | Bearing wear, imbalance, misalignment, looseness, lubrication loss | Rotor, stator, winding and insulation faults; voltage imbalance | Route vibration readings plus a separate electrical test | Smart Trac Ultra on the motor, Energy Trac in the motor's panel |
| Centrifugal pumps | Bearing wear, misalignment, imbalance, dry-running bearings | Load spikes and winding faults on the drive motor | Route readings that can miss faults between visits | Smart Trac Ultra on the pump, Energy Trac in the drive motor's panel |
| Gearboxes | Gear tooth wear, gear mesh degradation, bearing wear, lubrication loss | Overcurrent on the input motor as gear load rises | Wired probes for high-speed stages, routes for the rest | Smart Trac Ultra on the gearbox, Energy Trac in the input motor's panel |
| Fans | Imbalance, blade wear, looseness, bearing wear | Harmonics, sags and winding faults on the fan motor | Route readings, often skipped on hard-to-reach roof units | Smart Trac Ultra on the fan bearing housing, Energy Trac in its panel |
| Compressors | Bearing wear, misalignment, lubrication issues | Voltage imbalance and winding faults on the drive motor | Rack monitoring on large machines, routes on smaller ones | Smart Trac Ultra on the compressor, Energy Trac in its motor's panel |
Some assets need one data type, others need both. Tractian starts with an on-site Asset Risk Assessment and recommends the mix of mechanical and electrical monitoring per asset, based on its failure modes, criticality and operating context.
Worked example: a motor-driven process pump
Take a 75 hp centrifugal pump with a motor in the same skid. With SKF portable instruments, the pump gets a reading each time the route runs, often monthly; with a wired SKF, Emerson or Siemens system, it needs a new cable run to the nearest cabinet. A single-signal wireless sensor would cover the pump bearing alone.
With Smart Trac Ultra on the pump bearing housing and Energy Trac in the panel feeding the motor, a rising ultrasound level on a dry-running bearing and a winding insulation fault in the motor each show up as their own alert. The technician gets one diagnosis per fault, with severity and a next step, instead of two separate surveys.
How long does each approach take to install and start producing alerts?
Tractian sensors install in a day, with no cabling, no IT project and no dependency on plant WiFi, and teams can expect full visibility within the first 14 days while the models learn each machine's normal behavior. Wired systems take longer because cabling has to be scheduled around production.
A route program starts fast on paper, but its findings arrive as often as the route runs and as quickly as an analyst can review the spectra. Analyst-reviewed programs, including human-reviewed monitoring services such as Emerson's, add that review step between the data and the alert.
Each Smart Trac Ultra goes on with adhesive or a drill-and-tap mount and is running in minutes. Learn more about wireless vs wired condition monitoring.
Why does wireless multimodal monitoring give rotating equipment a fuller picture?
Wireless multimodal monitoring reads the mechanical and electrical side of the same rotating asset and diagnoses them together, so a fault in the bearing and a fault in the winding are separated instead of blurred into one vibration trend. Tractian builds this from two sensors and one AI model.
Smart Trac Ultra on the asset, Energy Trac in the electrical panel
Smart Trac Ultra mounts on one asset and samples vibration from 0 to 64,000 Hz, plus ultrasound, temperature and RPM. It is IP69K sealed and runs on a battery rated for up to 5 years.
Energy Trac goes into the electrical panel that feeds the motor, a non-invasive install with no process interruption. From there it reads current, voltage and power factor and flags rotor, stator, winding and insulation faults.
Janus turns both signals into one diagnosis
Janus learns how each asset normally runs under its load and regime, so a real deviation stands out from routine variation. It then checks the relevant sensor signals, work orders and technical documentation to narrow down the likely cause.
Alerts tell the team what's wrong, how severe it is and what to do next, with expert-vetted human review available when a case needs it. Learn more about multimodal condition monitoring.
Built for hazardous areas, plant networks and existing systems
- Hazardous locations: Smart Trac Ultra is Class I Div 1 ATEX/IECEx/NFPA compliant, so it can go on pumps and compressors in classified areas.
- Plant networks: sensor to receiver, receiver on 4G/LTE, so sensor traffic stays off plant WiFi.
- Existing systems: Tractian focuses on condition monitoring and sends alerts to the CMMS and ERP the plant already runs, through integrations with CMMS platforms (MaintainX, Fiix, UpKeep, Limble) and ERPs (SAP, Oracle NetSuite).
- Reporting: teams can query live maintenance data from Excel, Power BI or Tableau to build their own reliability reports.
Tractian monitors assets in 2,000+ operations. At Whirlpool, the team reached 95% coverage of previously unmonitored vibration points and recorded more than $1M in avoided costs from early interventions.
What should you ask before choosing CBM sensors for rotating equipment?
- Which of our motor faults can the system read without a separate electrical survey?
- How many days pass between a fault starting and someone seeing the data?
- What cable runs, conduit or shutdown windows does each new monitoring point require?
- Who interprets the spectra when our vibration analyst is off shift or retires?
- Does the sensor carry a Class I Div 1 rating for our classified areas?
- Do alerts land in our existing CMMS with a severity and a recommended action?
Frequently Asked Questions
Which sensors are used for condition-based maintenance on motors?
Motors need a mechanical sensor for bearing wear, imbalance and misalignment, and electrical monitoring for rotor, stator, winding and insulation faults. Tractian pairs Smart Trac Ultra on the motor with Energy Trac in the panel that feeds it, and Janus diagnoses both signal sets together.
Can one wireless sensor monitor vibration and ultrasound on the same asset?
Yes. Smart Trac Ultra picks up vibration and ultrasound, along with temperature and RPM, from the one asset it is mounted on. Ultrasound catches lubrication and friction problems, while vibration covers imbalance, misalignment and bearing defects.
Do wireless CBM sensors work in Class I Div 1 areas?
It depends on the sensor rating. Tractian sensors are Class I Div 1 ATEX/IECEx/NFPA compliant, so they can be installed on rotating equipment in classified areas such as solvent pumps and gas compressors.
Do wireless sensors need plant WiFi?
Many wireless sensors use a gateway on plant WiFi or Ethernet. Tractian sensors send data to a receiver, and the receiver connects over 4G/LTE, so monitoring runs without depending on the plant network.
How is electrical monitoring different from vibration monitoring?
Vibration monitoring reads mechanical behavior on the machine, such as bearing defects and misalignment. Electrical monitoring reads the motor circuit and catches rotor, stator, winding and insulation faults and voltage imbalance, which can develop with little change in vibration.
See which sensors your rotating assets need
Tractian maps your critical motors, pumps, gearboxes, fans and compressors to the mechanical and electrical monitoring each one needs, then installs in a day. Explore the Tractian condition monitoring platform to plan coverage for your plant, and see how this approach compares with older setups in legacy vs modern condition monitoring.