• Condition Monitoring
  • Condition Based Maintenance
  • Predictive Maintenance
  • Asset Management

Condition Monitoring and Reliability Engineering: How They Work Together

Alex Vedan

Updated Nov 23, 2026

10 min.

Key Points

  • Condition monitoring gives the reliability engineer a continuous, diagnosed record per asset to test FMEA, RCA and PM assumptions against.
  • A written ownership split keeps analysis with the reliability engineer and field execution with the maintenance team.
  • Tractian pairs Smart Trac Ultra mechanical data with Energy Trac electrical data, and Janus turns both into one diagnosis per asset.

Condition monitoring and reliability engineering work together as evidence and decision. The monitoring system records how each critical asset behaves, and the reliability engineer uses that record to rank criticality, update FMEA, run root cause analysis and change PM intervals.

When that record is missing, the same reliability tasks run on a handful of route readings and on what technicians remember. The sections that follow split ownership in a RACI table and trace one pump motor alert through an FMEA row, an RCA and a PM change, for the reliability engineer and the maintenance manager who share that work.

How does condition monitoring support reliability engineering?

Condition monitoring supports reliability engineering by supplying measured evidence per asset: vibration, ultrasound, temperature, electrical behavior and the faults diagnosed from them. The reliability engineer turns that evidence into four decisions: which assets matter most, which failure modes are real, why a failure happened and how often each PM task should run.

Reliability engineering sets the maintenance strategy, often through reliability-centered maintenance, and RCM assigns condition monitoring to failure modes that give measurable warning before they fail. Monitoring results then flow back and revise the strategy that placed the sensors.

Learn more about reliability-centered maintenance vs condition-based maintenance.

What does a reliability engineer do with condition monitoring data?

A reliability engineer uses condition monitoring data to rank asset criticality, check FMEA ratings against real behavior, find root causes from signals instead of opinions and fit PM intervals to what the assets show. Each of those tasks moves faster when the data arrives already collected and diagnosed.

Rank asset criticality

A criticality analysis scores each asset on the consequence of a failure and its likelihood. Consequence comes from production, safety and cost data, while likelihood is where monitoring history helps: a motor with three bearing alerts in a year deserves a different score than one with a flat baseline.

Tractian starts deployments with an on-site Asset Risk Assessment that evaluates asset criticality, failure modes, operating conditions and business impact, then recommends a monitoring scope for the highest-priority risks. The engineer can reuse that assessment as the first draft of the plant's criticality ranking.

Validate and update FMEA

An FMEA lists each failure mode with severity, occurrence and detection ratings. In many plants the occurrence and detection numbers were estimated in a workshop years ago and rarely revisited.

Condition monitoring data tests both numbers. Alert history shows how often a failure mode really appears, and the detection rating can drop once a sensor catches that mode weeks before functional failure rather than at the next monthly reading.

Run root cause analysis on real signals

Root cause analysis needs a timeline: when the signal left its baseline, what changed in the process and what the maintenance history shows. Continuous data gives that timeline down to the hour, which settles the usual "the machine failed" versus "it was run wrong" argument with timestamps instead of shift notes.

Janus, Tractian's industrial AI, lines up sensor signals against operating data, past repairs and asset documentation to shortlist probable causes. The engineer starts from those probable causes, a faster entry point than a whiteboard of 5 Whys.

Tune PM intervals and retire low-value tasks

PM intervals copied from OEM manuals or set after a past failure tend to stay fixed for years. With condition data per asset, the engineer can stretch an interval where the baseline is stable, shorten it where wear trends up and drop time-based inspections that a sensor now covers continuously.

Each change goes into the plant's CMMS as a revised PM plan, so planners schedule what the assets need rather than what the calendar says.

Who owns what between the reliability engineer and the maintenance team?

The reliability engineer owns analysis and decisions (criticality, FMEA, RCA, PM changes), the maintenance team owns execution in the field, and the condition monitoring platform supplies the data and the first diagnosis. In the RACI below, R is responsible, A is accountable, C is consulted and I is informed.

TaskTractian (what the platform supplies)Reliability engineerMaintenance planner and technicians
Asset criticality rankingAsset Risk Assessment findings and alert history per assetA, R: scores consequence and likelihood, sets the rankingC: adds repair time, spares lead time and field history
FMEA updatesDiagnosed faults and how often each failure mode shows upA, R: rescores occurrence and detection, adds missing modesC: confirms the failure mode found at teardown
Baselines and alert behaviorPer-asset baselines Janus learns under each load and regimeA: reviews alert behavior on critical assetsI: told when an asset is added or its scope changes
Alert triageDiagnosis naming the fault, its severity and a recommended fixC: joins on critical or repeat alertsA, R: planner prioritizes the job, technician inspects
Root cause analysisSignal timeline correlated with maintenance historyA, R: leads the RCA and signs off the causeC: supplies repair findings and failed parts
PM interval changesCondition trend per asset since the last PMA, R: proposes and approves the new intervalR: loads the revised plan into the CMMS and runs it
Bad-actor reviewAlert and fault history per asset over timeA, R: names the bad actors and the engineering fixC: adds labor hours and repeat work orders
Reporting to leadershipDashboards plus Power BI and SQL connectorsR: builds the reliability KPIsA: maintenance manager presents them to plant leadership

This is an example split. Adjust the letters to the plant's own org chart, for instance when a maintenance manager also carries the reliability role.

What does the workflow look like on a real asset?

On a centrifugal pump motor, the workflow runs alert, diagnosis, root cause, FMEA update and PM change. The walkthrough below is an example built for illustration, and its figures are example values, not customer data.

Example setup: a 75 kW (100 hp) motor drives a cooling water pump ranked A in criticality. A Smart Trac Ultra is mounted on the motor's drive-end bearing housing, and an Energy Trac sits in the electrical panel that supplies the motor's circuit.

  1. Day 0, mechanical alert (example). Ultrasound and high-frequency vibration at the drive-end bearing climb above the baseline Janus learned for this motor. The diagnosis reads early bearing wear with degraded lubrication, moderate severity, with a regrease and recheck as the next step.
  2. Day 9, electrical alert (example). Electrical data from the panel shows a voltage imbalance across the three phases and an early winding fault signature in the current. Janus links it to the open bearing case on the same asset.
  3. Root cause (example). The engineer lines up both timelines and sees that the imbalance started first. Imbalance raises winding temperature, and that heat can shorten grease life in a nearby bearing, so one cause, a pitted contactor on one phase, explains both alerts.
  4. FMEA update (example). The bearing row gets a new detection method and lower detection rating, and a winding degradation row is added for this motor class.
  5. PM change (example). The monthly route reading on this pump is retired, regreasing moves to condition-based, and a contactor inspection is added to the quarterly PM for that panel.

The FMEA rows before and after the two alerts, with example ratings on a 1 to 10 scale:

FMEA field (example values)Bearing wear: beforeBearing wear: afterWinding degradation: new row
Detection methodRoute vibration reading once a monthContinuous vibration and ultrasound on the motorElectrical data from the motor control panel
Severity (1 to 10)888
Occurrence (1 to 10)45 (alert history shows the mode is more frequent)3
Detection (1 to 10)733
RPN (S x O x D)8 x 4 x 7 = 2248 x 5 x 3 = 1208 x 3 x 3 = 72

Example values for illustration. Severity stays at 8 because the consequence of losing the pump has not changed; the RPN drops because detection improved, even though alert history raised occurrence.

A vibration-only program would have caught the bearing and likely replaced it, leaving the contactor to wear out the next bearing. Combining mechanical and electrical data on one asset is what turned two alerts into one root cause.

Why does continuous data change reliability work compared with route data?

Continuous data changes reliability work because the engineer analyzes a running record of each asset rather than one reading a month. With route data, a failure mode that develops between visits can reach functional failure unseen, and the FMEA detection rating has to carry that gap.

Legacy programs come in two forms. Route programs use portable collectors: SKF describes its portable instruments as the basis of a periodic condition monitoring program, and the Emerson AMS 2140 is a route-based portable vibration data collector.

Wired online systems, among them Bently Nevada 3500 protection racks and Siemens SIPLUS CMS1200 modules designed for the SIMATIC S7-1200 controller, read continuously on the machines they are cabled to. Route and wired setups depend on a technician walking a route, or on cable runs and controller work per machine, so plants tend to keep them for a short list of assets.

A Tractian sensor mounts with adhesive or drill-and-tap in minutes, needs no wiring or plant Wi-Fi, and samples at a default 10-minute interval. That puts continuous, multimodal coverage within reach of the balance-of-plant pumps, fans and gearboxes that route programs visit monthly.

On the P-F curve, the useful window runs from the first detectable sign (P) to functional failure (F). Continuous sampling puts the first reading close to P instead of at the next route date, which hands planners more of that window to schedule the repair.

Learn more about legacy and modern condition monitoring approaches.

Which reliability metrics improve with condition monitoring?

The reliability metrics that move first with condition monitoring are MTBF, the share of failures caught before breakdown, planned versus unplanned work and the detection ratings in the FMEA. Each one depends on spotting a failure mode early enough to plan the repair.

  • MTBF: rises when repairs happen before secondary damage, such as a seized bearing scoring the shaft. Track it per asset with the MTBF calculator.
  • Failures caught before breakdown: the count of functional failures that had a prior alert, divided by the total. A rising share shows the monitoring scope matches the real failure modes.
  • Planned versus unplanned work: the share of maintenance labor hours spent on scheduled jobs. Early detection moves hours out of the emergency column.
  • FMEA detection ratings: the average detection score on critical assets. It falls as sensors take over failure modes that routes used to miss.

Whirlpool used Tractian to reach 95% coverage of vibration points that had no monitoring before, and early interventions avoided $1M+ in downtime and production-loss costs. Tractian runs in 2,000+ operations, and the company reports $1.6B in avoided losses returned to them.

What should the CM platform give a reliability engineer?

A condition monitoring platform should give the reliability engineer mechanical and electrical signals per asset, a diagnosis that explains the fault and its severity, and a clean path for data into the CMMS, ERP and BI tools the plant already runs. Raw spectra with no diagnosis push the engineer back into data collection.

Mechanical and electrical signals per asset

Smart Trac Ultra is fixed to a single asset, where it measures vibration, ultrasound, temperature and RPM. Energy Trac goes in the motor control panel and installs without a process interruption; from the current, voltage and power factor of that circuit it detects voltage imbalance along with rotor, stator, winding and insulation faults.

Together they make up Tractian multimodal monitoring: mechanical and electrical data on the same asset, combined into one view of its health. Tractian sensors are Class I Div 1 ATEX/IECEx/NFPA compliant, have a battery life of up to 5 years and send data sensor to receiver, with the receiver on 4G/LTE.

Diagnoses from Janus: what's wrong, how severe it is, what to do

Janus, trained on proprietary data from real machines, learns the normal behavior of each asset at its operating load and regime, which separates genuine deviations from day-to-day variation. With Auto Diagnosis, each alert carries the failure mode, its likely root cause and a recommended action.

For a critical asset where the engineer wants a second opinion, Tractian adds expert-vetted human review. Each validated diagnosis is stored and reused by Janus in later investigations on that asset and similar ones.

Data out to the tools already in use

On the software side, Tractian stays on condition monitoring and asset health and connects through API to the CMMS the plant uses, for example Limble, UpKeep, Fiix or MaintainX, and to ERPs like SAP and Oracle NetSuite. Power BI and SQL connectors feed the engineer's own reports, such as MTBF by asset class or alert-to-repair lead time.

Most Tractian customers reach full operation inside 14 days, as the AI models calibrate to how each machine runs.

Learn more about setting up a condition monitoring program.

Tractian pricing is set per monitored asset: share the asset list the reliability program has to cover, and a Tractian specialist returns a custom quote built on it.

Frequently Asked Questions

Is condition monitoring part of reliability engineering?

Yes. Condition monitoring is one of the maintenance tasks reliability engineering selects, usually through RCM, for failure modes that give measurable warning. The reliability engineer decides where it applies and uses its data to update criticality, FMEA and PM plans.

What is the difference between RCM and condition monitoring?

RCM is a method for choosing the right maintenance task for each failure mode. Condition monitoring is one of those tasks: measuring asset condition to catch a failure mode between its first sign and functional failure. RCM decides where monitoring goes, and monitoring supplies the evidence that RCM decisions are tested against.

How does condition monitoring improve MTBF?

Condition monitoring improves MTBF by catching failure modes early enough to repair them before secondary damage, such as a worn bearing scoring the shaft. Fewer functional failures per operating hour raise MTBF. The gain shows first on the monitored assets, so track MTBF per asset rather than plant-wide.

Can condition monitoring data be used in FMEA?

Yes. Alert history shows how often each failure mode really occurs, which updates the occurrence rating, and continuous detection lowers the detection rating for modes the sensors catch. Electrical monitoring can also surface failure modes the original FMEA missed, such as winding degradation from voltage imbalance.

Does a plant need a reliability engineer to run condition monitoring?

No. Plants without a dedicated reliability engineer can run condition monitoring when the platform delivers diagnoses instead of raw spectra, and Tractian alerts name the fault, rate its severity and give the next step. A reliability engineer gets more from the same data by feeding it into FMEA, RCA and PM decisions.

To see how per-asset mechanical and electrical data would feed a plant's FMEA and PM plans, explore Tractian condition monitoring.

Alex Vedan
Alex Vedan

Director

Alex Vedan, Marketing Director at Tractian, develops impactful strategies that empower industrial clients across North America and LATAM to achieve operational excellence. By aligning innovation with customer needs, he ensures Tractian solutions drive meaningful improvements in efficiency and reliability.

Share

Start Exploring Tractian Condition Monitoring