Key Points
- A fixed threshold flags a motor or pump once a reading crosses a set limit, which tends to land late in the failure.
- A trend read against the asset's own baseline flags the same fault weeks earlier, while parts can still ship at standard lead times.
- Electrical motor faults, such as broken rotor bars, need current data next to vibration to show up early.
On a motor or a pump, condition-based maintenance acts when a reading crosses a limit set in advance. Predictive maintenance acts when the trend in that reading shows where it is heading. Both can use the same sensor on the same bearing housing; what changes is the alert date, and with it how much time the maintenance manager has to order a bearing or an impeller and plan the repair.
This guide runs one motor and one centrifugal pump through the same failure under both approaches, week by week, and shows which faults need electrical data on top of vibration. Learn more about the broader difference between condition-based and predictive maintenance.
What is the difference between condition-based and predictive maintenance on a motor or pump?
Condition-based maintenance (CBM) triggers work when a measured value on a motor or pump passes a fixed limit. Predictive maintenance (PdM) tracks how that value changes against the asset's normal behavior and raises the alert when the trend points to a developing fault, usually well before the limit is reached.
The split sits in the decision rule; the hardware can be identical. A CBM rule reads like "inspect the motor when overall velocity passes 2.8 mm/s." A PdM rule reads like "this motor's ultrasound level has climbed 12 dB at the same load in four weeks, and a bearing tone has appeared."
On the P-F curve, the CBM rule fires at a point set by the limit, and the PdM rule fires at the first change that stands out from the asset's baseline. On rotating equipment, that gap is often several weeks. Condition-based maintenance stays useful on its own for simple, spare-backed assets, as the decision table further down shows.
How does a threshold alert work on a motor and a pump?
A threshold alert compares one reading, such as overall vibration velocity, bearing temperature or discharge pressure, with a fixed alarm level and a higher danger level. It fires when the reading passes the line, whatever the asset's load, speed or recent history.
Vibration severity limits on a motor
For a motor between 15 kW and 300 kW on a rigid base, ISO 10816-3 (now ISO 20816-3) puts the zone boundaries at about 1.4, 2.8 and 4.5 mm/s RMS. These are general industry ranges: many plants set the alarm at the 2.8 mm/s boundary and the danger level at 4.5 mm/s, then adjust per machine.
The weak spot is what overall velocity measures. It is dominated by energy at running speed, so an early inner-race defect, which adds small high-frequency tones, barely moves the number until the damage has spread. On a motor fed by a variable frequency drive, one fixed limit can also miss a fault at low speed and trip on a resonance at another speed, which is why vibration alarm thresholds work better when set per machine and speed.
Pressure, vibration and temperature limits on a pump
Pump thresholds usually combine an overall vibration alarm on the bearing housing, a low discharge pressure alarm and a high bearing temperature alarm. Each one covers a different symptom, and each one tends to react after the fault has done some of its damage.
Cavitation produces random high-frequency bursts and pressure pulsations that an overall velocity alarm averages away. A pressure alarm set at 85% of design head trips once impeller erosion has already cost head, and bearing temperature rises late in most bearing failures.
Fixed pump limits also raise false alarms during startups and low-flow runs, which teaches crews to ignore them. Continuous pump monitoring tracks these signals together instead of one limit at a time.
How does a predictive alert work on the same assets?
A predictive alert compares each reading with how that specific motor or pump normally runs at its current load and speed, then flags a change in the trend or a known fault pattern before any fixed limit is crossed. The output names the fault and its severity.
Three things make that possible. The baseline is learned per operating regime, so a pump at 60% flow is compared with itself at 60% flow. The model watches the rate of change, so a reading that doubles in three weeks stands out even while it is far below the alarm.
The third is fault signatures. Bearing defect frequencies, vane-pass peaks and ultrasound levels point to a specific failure mode instead of a general rise in vibration. Tractian's industrial AI, Janus, is built around this approach: it learns how this asset normally runs under this load and regime, so real deviations stand out from routine variation.
What alert date would each approach give on the same failure?
In the two examples below, the trend-based alert comes six weeks before the fixed alarm on the motor and eight weeks before it on the pump. Both walkthroughs are illustrative examples built on general industry ranges, not readings from a specific Tractian customer site.
Motor: inner-race bearing defect
The asset is a 75 kW (100 hp), four-pole motor running at about 1,780 rpm on a rigid base, driving a process fan through a coupling. The plant sets its vibration alarm at 2.8 mm/s and its danger level at 4.5 mm/s. Ultrasound steps follow a common rule of thumb: about 8 dB over baseline points to a lubrication problem, and 16 dB or more to early bearing damage.
| Week | Overall velocity (mm/s RMS) | Ultrasound vs baseline | Inner-race tone (BPFI) | Threshold status (alarm 2.8, danger 4.5) | Trend status | Action triggered |
|---|---|---|---|---|---|---|
| Week 0 | 1.5 | Baseline | Not visible | Normal | Baseline learned at this load | Routine operation |
| Week 2 | 1.5 | +8 dB | Not visible | Normal | Lubrication flag | Grease the bearing on the next round |
| Week 4 | 1.6 | +12 dB after greasing | Small peak | Normal | Inner-race pattern confirmed, alert raised | Order the bearing at standard lead time |
| Week 6 | 1.9 | +16 dB | Peak with running-speed sidebands | Normal | Severity raised | Book the swap for the planned stop |
| Week 8 | 2.4 | +20 dB | Harmonics present | Normal | Repair window | Bearing replaced on the predictive path |
| Week 10 | 3.1 | +24 dB | Harmonics, raised noise floor | Alarm | Fault already removed | First alert on the threshold path |
| Week 12 | 4.7 | Erratic | Broadband noise | Danger | Fault already removed | Emergency stop if no bearing is on site |
Illustrative motor example. Readings are general industry ranges, not measured data.
On the predictive path, the alert lands in week 4 and the bearing is replaced in a planned stop in week 8, on normal shift hours. On the threshold path, the first alert lands in week 10 and the danger level follows two weeks later, which leaves little time if the bearing is not in stock.
If the fan motor's bearing runs on to seizure, the inner race can spin on the shaft and score the journal. A planned bearing swap then turns into a shaft repair or a motor rewind, often started on a night or weekend callout.
Pump: cavitation and impeller wear
The asset is an end-suction centrifugal pump with a six-vane impeller, drawing process water from a sump whose level drops on the night shift. The plant alarms at 4.5 mm/s overall vibration and at 85% of design discharge pressure. When the sump runs low, the margin between available and required suction head shrinks and the pump starts to cavitate.
| Week | Overall velocity (mm/s RMS) | High-frequency energy | Discharge pressure (% of design) | Threshold status (vibration 4.5, pressure 85%) | Trend status | Action triggered |
|---|---|---|---|---|---|---|
| Week 0 | 2.3 | Baseline | 100% | Normal | Baseline learned per flow and sump level | Routine operation |
| Week 1 | 2.4 | Bursts at low sump level | 99% | Normal | Cavitation pattern tied to suction level, alert raised | Raise the minimum sump level, clean the suction strainer |
| Week 3 | 2.5 | Bursts on the night shift | 97% | Normal | Pattern repeats under the same conditions | Order an impeller, plan an inspection |
| Week 6 | 3.2 | Rising, vane-pass peak growing | 93% | Normal | Head loss at the same speed flagged | Swap the impeller in the planned stop |
| Week 9 | 4.6 | High | 87% | Vibration alarm | Impeller already swapped | Threshold path raises its first alert |
| Week 11 | 5.3 | High | 84% | Vibration and pressure alarms | Impeller already swapped | Unplanned stop if no impeller is in stock |
Illustrative pump example, built on typical ranges for centrifugal pumps rather than site data.
The trend picks up the cavitation bursts in week 1 because they repeat at low sump level and fade when the level recovers. That points the team at a suction-side cause they can fix the same week, and it gives eight weeks to have an impeller on site before the erosion shows up in the alarms. Left alone, pump cavitation pits the impeller vanes and loads the bearings and seal.
Which motor and pump faults need electrical data as well as vibration?
Rotor bar defects, stator winding faults, insulation degradation and voltage imbalance tend to appear in a motor's current and voltage before they show up as vibration. Covering them early takes electrical monitoring on the motor's circuit alongside the vibration sensor on the asset.
| Fault | What vibration and ultrasound show | What current and voltage show |
|---|---|---|
| Inner or outer race bearing defect | Early: ultrasound rise, then bearing tones | Weak and late signal |
| Unbalance or misalignment | Clear peaks at 1x and 2x running speed | Limited |
| Broken rotor bars | Late: pole-pass sidebands once the defect has grown | Early: sidebands around line frequency in the current spectrum |
| Stator winding fault | Limited until heat or looseness follows | Current imbalance between phases |
| Insulation degradation | Little mechanical sign before breakdown | Electrical fault signature in the current waveform |
| Voltage imbalance | Indirect, through winding heat | Measured directly per phase |
| Pump cavitation | High-frequency bursts on the bearing housing | Load swings in motor current |
| Pump blockage or dry running | Shift in vibration pattern | Current draw moves with the load change |
Typical detection by signal type, based on general industry guidance. Results vary with motor size, load and drive type.
Broken rotor bars are the clearest case. In the current spectrum, they show as sidebands around line frequency at a stage when vibration looks normal, a method known as motor current signature analysis. Insulation and winding problems can leave little mechanical trace until the motor trips.
Tractian covers this with Energy Trac, installed in the electrical panel that feeds the motor, with no process interruption. It tracks current, voltage and power factor per asset and detects rotor, stator, winding and insulation faults as well as voltage imbalance. Its electrical signature analysis picks up fault signatures in the current waveform months before secondary damage appears.
Paired with a Smart Trac Ultra on the motor, that gives Tractian multimodal monitoring: mechanical and electrical signals combined by Janus into one view of the motor's health, so a winding fault and a bearing fault on the same machine show up in the same place, each with its own diagnosis.
When is a threshold enough, and when is a forecast worth it?
A threshold is usually enough on a motor or pump with a standby unit and parts on the shelf, where a failure costs one part and a restart. A forecast pays off where a failure stops production, the spare takes weeks to arrive, or the fault would wreck more than the part that started it.
| Factor | A threshold is usually enough when | A trend forecast is worth it when |
|---|---|---|
| Criticality | A failure slows one line or a utility with slack | A failure stops production or a safety system |
| Redundancy | An installed standby pump or motor takes over | The asset runs without a standby |
| Spare lead time | The bearing, seal or impeller is on the shelf | The motor, impeller or rewind takes weeks or months |
| Duty cycle and load | Constant speed and steady load | VFD speed changes, batch cycles or variable suction conditions |
| Cost of a missed fault | Replace the part and restart | Secondary damage to the shaft, housing or windings |
| Who reads the data | A vibration analyst reviews readings in-house | Generalist mechanics need the fault and next step spelled out |
Plants often run both. Thresholds stay on as a safety net, and forecasts go on the assets in the right-hand column.
The forecast column is also where the maintenance manager's numbers move. Faults caught early become planned repairs on normal shift hours, which cuts weekend callouts and overtime and lifts mean time between failures. Each early catch is also logged with the asset, the fault and the repair it replaced, so the budget review has proof behind it.
How does Tractian monitor motors and pumps?
Tractian mounts a Smart Trac Ultra on each motor and each pump it covers, adds Energy Trac in the panel where electrical faults matter, and has Janus read both against each asset's own baseline. The alert names the fault, ranks it by severity and asset criticality, and spells out the next step.
Smart Trac Ultra reads vibration, ultrasound, temperature and RPM from the asset it is mounted on, so the motor and the pump each get their own sensor. Tractian predictive maintenance detects signs of wear or failure early, often weeks in advance, which is the lead time the walkthroughs above depend on.
- Quick start: sensors install in a day, with no cabling, no IT project and no dependency on plant WiFi, and teams can expect full visibility within the first 14 days.
- Connectivity: sensor to receiver, receiver on 4G/LTE.
- Hazardous areas: the sensors are Class I Div 1 ATEX/IECEx/NFPA compliant, for pumps in classified zones.
- Integrations: alerts flow into the CMMS and ERP the team already runs, including MaintainX, Fiix, UpKeep, Limble, SAP and Oracle NetSuite, through Tractian integrations. Power BI and SQL connectors support custom reporting.
- Pricing: Tractian pricing is per monitored asset. Name the motors and pumps you want to protect, and a Tractian specialist will put a custom quote together.
Ingredion knows the pump scenario well: before Tractian, a critical pump with no spare on hand failed and caused a three-day shutdown. After rolling out Tractian condition monitoring, the team caught failures on critical pumps and other assets and avoided 168 hours of downtime through early warnings, with $1.0M in production savings and $223K in maintenance savings at one facility.
Tractian is used in 2,000+ operations, with $1.6B in avoided losses returned to customers. Learn more about machine health monitoring systems for motors.
Frequently Asked Questions
Is predictive maintenance better than condition-based maintenance for pumps?
For critical pumps without a standby, predictive maintenance usually gives more lead time, because it flags cavitation and impeller wear as trends instead of waiting for a pressure or vibration alarm. For spare-backed utility pumps, a well-set threshold is often enough. Many plants run thresholds as a safety net and add trend-based alerts on the pumps that can stop production.
What vibration level should trigger a motor alarm?
As a general starting point, ISO 10816-3 and ISO 20816-3 place the zone limits for a medium-size motor on a rigid base near 1.4 mm/s (A/B), 2.8 mm/s (B/C) and 4.5 mm/s (C/D) RMS. Plants often alarm at 2.8 mm/s and treat 4.5 mm/s as the danger level. Those limits work best when adjusted per machine, mounting and speed.
Can vibration monitoring detect motor electrical faults?
Partly. Vibration can show some electrical faults, such as rotor bar defects, through pole-pass sidebands, but usually at a later stage. Stator winding, insulation and voltage imbalance problems show up more clearly in current and voltage data, which is why electrical monitoring is paired with vibration on critical motors.
How far in advance can predictive maintenance flag a bearing failure?
It depends on the bearing, the load and the signals used, but trend-based monitoring often flags a developing defect weeks ahead of a fixed vibration alarm. Ultrasound and bearing defect frequencies tend to move first, overall velocity later. With Tractian, alerts on wear or failure often arrive weeks in advance.
Do you need both vibration and current monitoring on a motor?
On critical motors, combining both covers more failure modes. Vibration and ultrasound catch bearing, alignment and balance problems early, and current and voltage data catch rotor, stator, winding and insulation faults. On low-criticality motors with a spare on the shelf, vibration alone is often enough.
Start with the motors and pumps whose failure would stop a line, and see how Tractian condition monitoring sets their baselines and flags the first change.